Playbright

Inclusive play

Can a child with a cochlear implant use a plastic slide?

The child can slide. The sound processor should not. Every implant maker's instructions agree on that, and a playground can make the rule far easier to live with.

Updated 8 min readInclusive play

Short answer

Yes. A child with a cochlear implant can use a plastic slide, but the device instructions from three implant makers say to take the external sound processor off first, completely rather than just switched off. Static built up on a plastic chute can, in rare cases, damage the system or corrupt the processor's program. A metal slide avoids the problem.

On this page
  1. The short answer, and who says so
  2. What the device instructions say, side by side
  3. Why two answers circulate
  4. How to do it at the slide
  5. What else counts as a plastic slide
  6. What a playground can do about it
  7. Where this answer stops applying
  8. What to do next

The short answer, and who says so

Yes, a child with a cochlear implant can use a plastic slide. What should not go down the slide is the external sound processor. Take it off first, completely, and put it back on once the child has discharged.

That is not one clinic's caution. It is in the current device instructions from three implant makers, and in the guidance of two pediatric cochlear implant programs. Nothing about the child's own safety changes: St. Louis Children's Hospital says a child will be safe after a static shock to the arm, and the concern is a discharge directly to the external speech processor2.

Playground guidance says nothing about it. The CPSC's Public Playground Safety Handbook does not mention static electricity at all7, and vision and hearing design treats cochlear implants as an acoustics problem. Static is a separate, physical one, and it has a design answer.

What the device instructions say, side by side

Manufacturers are named here only as the authors of their own device instructions. Always check the manual that came with the child's model, since wording varies between documents and editions.

SourceWhat it says about plastic slidesDetail worth knowing
Cochlear, Nucleus Important Information (2022 and 2024 editions)Remove the sound processor before activities that create extreme electrostatic discharge, such as playing on plastic slides45In rare cases a discharge can damage electrical components or corrupt the program in the sound processor
MED-EL, RONDO 3 user manualAlways remove the audio processor before touching plastic play equipment, e.g. children's slides6Switching it off may not be enough; remove it from the body and do not touch the implant site afterwards
Advanced Bionics, static flyer for schools (2015)Remove the sound processor and headpiece before plastic slides, plastic tubes and trampolines, or redirect the activity3Systems carry numerous safeguards, but a remote possibility of damage remains at extremely high static levels
CID, pediatric audiology guidanceAvoid plastic playground equipment; metal slides are a great, inclusive option; if plastic is unavoidable, remove the processor completely1The risk is that the map, the child's listening program, is erased
St. Louis Children's HospitalLists plastic slides, trampolines, balloons and plastic ball pits; remove the processor for them2Touch something else first to ground yourself before touching the processor
Three device makers and two pediatric programs, all saying the same thing about plastic slides. None of them says switching the processor off is a substitute for removing it.

Two details are easy to miss. The first is that "off" is not "removed". MED-EL states that switching the processor off may not prevent damage, and Advanced Bionics names the headpiece as well as the processor. The second is that the Cochlear warning appears, in the same words, in a 2022 document and a 2024 one, so this is current instruction rather than a leftover from older hardware.

Why two answers circulate

Parents hear two things. One is "never let them near a plastic slide". The other is "modern implants are protected, so it does not matter any more". Both contain a true sentence, and neither is the instruction.

The protection is real. Advanced Bionics says its systems are robustly designed with numerous safeguards against static, which greatly minimizes the risk of damage3. MED-EL describes several internal safety features and says the most likely result of a discharge is a short interruption of stimulation or a controlled shutdown of the processor6. CID notes that current implant design limits the risk1.

The residual risk is also real, and all three makers name it. Cochlear says a discharge can in rare cases damage components or corrupt the program4. MED-EL says there is a small risk that external or internal equipment is damaged, and that in rare cases the user may experience uncomfortably loud hearing sensations6. CID adds that if the child's map is erased, they will not be able to hear from the implant until it is restored1.

So the settled answer is this: the risk is low, the consequence is a child who cannot hear until the audiologist fixes it, and removing the processor for the length of a slide costs almost nothing. That is why every source still says to take it off. The "it does not matter" version persists because the reassurance is quoted without the instruction that follows it.

How to do it at the slide

The grounding step comes straight from the instructions. MED-EL tells a charged user to discharge by touching a radiator, a water tap or any grounded metal object, and not to let another person touch the external parts unless both have discharged6. Cochlear says to touch something conductive, such as a metal door handle, before the implant system contacts any object or person4. CID and St. Louis Children's both tell the adult to ground themselves before touching the device12. On a playground, a steel post set in the ground is the obvious thing to touch.

If the processor stops working after a slide, MED-EL's manual says to switch it off, wait a few minutes, switch it on again, and call the healthcare provider if it does not come back6. Carry the audiologist's number and, if the child has one, the backup processor.

What else counts as a plastic slide

The sources name the same handful of activities. Advanced Bionics lists sliding on plastic slides, playing on trampolines and plastic tubes3. St. Louis Children's lists plastic slides, trampolines, balloons and plastic ball pits2. On a playground that means tube slides and crawl tubes as well as open chutes; see tunnels and crawl spaces for how common molded plastic tubes are on composite structures. At home it means the backyard trampoline and the plastic slide that comes bundled with most playsets, which is worth weighing when choosing a playset.

Surfacing is not on any source's list. The rubber mulch guide notes that dry rubber in dry climates generates noticeable static on slides; for most children that is a nuisance, but for a child wearing a processor it is one more reason to follow the removal rule rather than trust the conditions.

What a playground can do about it

This is where a site owner has real choices, and none of them is expensive compared to the structure they sit on.

Put at least one metal chute on the site. CID's own recommendation is metal slides as the inclusive option1, and it is the only change that lets a child keep hearing their friends all the way down. A stainless chute costs more than a plastic one, roughly $1,500 to $6,000 against $600 to $2,500 as 2026 US equipment only pricing in the slides guide, and it lasts for decades. The broader trade-offs are in materials: steel, wood and plastic.

Put it beside the plastic one, not somewhere else. A metal chute alongside the plastic chute from the same deck, or a stainless embankment slide next to the main structure, means the child with the implant slides with the group instead of being sent to a different corner. That is the difference beyond compliance describes between a counted component and shared play.

Deal with the heat. Stainless in full sun is a burn risk, and a metal slide nobody can touch in July is not an inclusive option. Face the chute away from afternoon sun or shade it, following heat and burn risk and shade and heat design.

Give the exit a metal touch point. A child who comes off a plastic chute charged will discharge on the first grounded thing they touch. Where the slide exit leads straight onto a metal ladder or rail, that is a hand on metal, which is exactly what the manufacturers ask for, provided the processor is still off. The problem is the kind of play loop covered in layout and circulation: slide, ladder, deck, slide again, with the processor back on in between or never removed. A steel post or rail at the exit, at hand height, and a bench nearby where an adult can hold the device, turn the routine into something a family can repeat without thinking.

Where this answer stops applying

This page covers cochlear implant sound processors and the instructions quoted above. It does not cover hearing aids or bone conduction devices, whose makers publish their own guidance. It does not give a humidity or weather threshold, because none of the sources gives one. And it does not replace the child's own device manual or audiologist: models change, and so do instructions.

It also does not make a playground unsafe. A plastic slide meeting the geometry in slide safety is a normal piece of equipment. The static question is about protecting a device, and the CPSC handbook and the standards summarized in CPSC, ASTM and standards are silent on it.

What to do next

If you are a parent, adopt the removal routine above and use the parent's playground check to spot metal slides at the parks you visit. If you manage a site, add one line to your next inclusive site audit: is there a metal chute beside the plastic ones, in shade, with a metal touch point at the exit? If you are writing a brief, specify it now, while it is a line item rather than a retrofit.

Frequently asked questions

Is switching the sound processor off enough before a plastic slide?

No. The MED-EL RONDO 3 manual says switching the audio processor off may not be enough to prevent damage from static discharge, and tells users to remove it from the body completely. The Advanced Bionics flyer says to remove both the sound processor and the headpiece. Take the whole external device off and put it somewhere away from the slide.

Can a child with a cochlear implant go down a metal slide with the processor on?

CID calls metal slides a great, inclusive option and advises avoiding plastic playground equipment. None of the three makers' instructions reviewed here lists metal slides as a static source; they name plastic slides. A metal chute is the one slide choice that removes the reason to take the processor off, though a hot stainless chute brings its own problem in summer.

Does static only affect the part worn on the head?

Mostly, but not only. St. Louis Children's says a shock on the arm is safe and the concern is discharge directly to the external processor. CID warns that further shocks to the external processor carry a chance of damaging the internal part, and Advanced Bionics says high levels of static can theoretically damage both internal and external equipment.

What should we do if the processor stops working after a slide?

The MED-EL manual says to switch the processor off, wait a few minutes and switch it on again, then contact your healthcare provider if it does not come back on. CID points families to the child's audiologist when a program is lost, since a corrupted or erased map has to be reloaded before the child can hear through the implant again.

Are trampolines and ball pits a problem too?

Yes, by the same logic. Advanced Bionics lists trampolines and plastic tubes alongside plastic slides, and St. Louis Children's lists trampolines, balloons and plastic ball pits as activities that generate static. Both say to remove the processor for them. Treat any long plastic contact with a lot of rubbing the way you would treat a plastic slide.

Sources

  1. 1
    Understanding and minimizing the effects of static electricity on cochlear implants. CID (Central Institute for the Deaf)Johanna Lowell, pediatric audiologist, undated
  2. 2
    Cochlear implant precautions. St. Louis Children's HospitalCochlear implant program
  3. 3
    Static electricity and cochlear implants: commonly asked questions. Advanced Bionics, 2015Tools for Schools flyer 027-M608-03
  4. 4
    Nucleus cochlear implants: Important Information for cochlear implant recipients. Cochlear, 2022Document D1993471, Canada edition, Electrostatic discharge section
  5. 5
    Nucleus CI600 Series Implants: Important Information for recipients. Cochlear, 2024Document D1803421, Europe, Middle East and Africa edition
  6. 6
    Cochlear Implants User Manual: RONDO 3 Audio Processor. MED-ELManual AW40434_1.0 (English US), General precautions and warnings
  7. 7
    Public Playground Safety Handbook. US Consumer Product Safety Commission, 2010Publication 325, searched for any mention of static